2.19 Digital Imaging FMS
Protocol: The student will be able to produce a full mouth radiographic survey.
Criteria:
Student completed procedure protocol accurately | Successful (S) |
Student did not complete procedure protocol accurately | Unsuccessful (U) |
Procedures Protocol |
Complete armamentarium assembled |
Turned on the X-ray machine and checked the setting |
Washed hands |
Placed all necessary barriers |
Positioned the patient |
Asked the patient to remove eyeglasses and all piercings |
Draped the patient with a lead apron and a thyroid collar |
Washed hands and put on clean exam gloves |
Used a mouth mirror to inspect the oral cavity |
Asked the patient to remove any removable prosthetic appliances |
Assembled the required film holding instruments |
Maxillary Centrals |
Selected the correct exposure setting |
Inserted the sensor vertically into anterior holder |
Centered the sensor between the central incisors |
Positioned the PID on the centre of the sensor |
Image is of diagnostic quality |
Maxillary Lateral/Cuspid Region |
Selected the correct exposure setting |
Inserted the sensor vertically into the anterior holder |
Centered the sensor between the lateral and canine |
Positioned the PID on the centre of the sensor |
Image is of diagnostic quality |
Maxillary Premolar Region |
Selected the correct exposure setting |
Inserted the sensor horizontally into the posterior holder |
Centered the sensor on the premolars |
Positioned the PID on the centre of the sensor |
Image is of diagnostic quality |
Maxillary Molar Region |
Maxillary Molar Region |
Inserted the sensor horizontally into the posterior holder |
Centered the sensor on the second molar |
Positioned the PID on the centre of the sensor |
Image is of diagnostic quality |
Bite Wings |
Placed the sensor for a right molar bitewing exposure |
PID centered on sensor |
Used the correct exposure |
Image is of diagnostic quality |
Placed the sensor for a right premolar bitewing exposure |
PID centered on sensor |
Used the correct exposure |
Image is of diagnostic quality |
Placed the sensor for a left premolar bitewing exposure |
PID centered on sensor |
Used the correct exposure |
Image is of diagnostic quality |
Placed the sensor for a left molar bitewing exposure |
PID centered on sensor |
Used the correct exposure |
Image is of diagnostic quality |
Mandibular Centrals |
Selected the correct exposure setting |
Inserted the sensor vertically into anterior holder |
Centered the sensor between the central incisors |
Positioned the PID on the centre of the sensor |
Image is of diagnostic quality |
Mandibular Lateral/Cuspid Region |
Selected the correct exposure setting |
Inserted the sensor vertically into the anterior holder |
Centered the sensor between the lateral and canine |
Positioned the PID on the centre of the sensor |
Image is of diagnostic quality |
Mandibular Premolar Region |
Selected the correct exposure setting |
Inserted the sensor horizontally into the posterior holder |
Centered the sensor on the premolars |
Positioned the PID on the centre of the sensor |
Image is of diagnostic quality |
Mandibular Molar Region |
Selected the correct exposure setting |
Inserted the sensor horizontally into the posterior holder |
Centered the sensor on the second molar |
Positioned the PID on the centre of the sensor |
Image is of diagnostic quality |
Overall Evaluation |
Completed in less than 45 minutes |
Completed in 60 minutes or less |
Images are of diagnostic quality and do not require more than 7 retakes |
Documents chart according to protocol |
Safety measures followed |
Infection control protocols followed |
Demonstrates professionalism and appropriate communication skills |