2.19 Digital Imaging FMS

Protocol: The student will be able to produce a full mouth radiographic survey.

Criteria:

Student completed procedure protocol accurately Successful (S)
Student did not complete procedure protocol accurately Unsuccessful (U)
Procedures Protocol
Complete armamentarium assembled
Turned on the X-ray machine and checked the setting
Washed hands
Placed all necessary barriers
Positioned the patient
Asked the patient to remove eyeglasses and all piercings
Draped the patient with a lead apron and a thyroid collar
Washed hands and put on clean exam gloves
Used a mouth mirror to inspect the oral cavity
Asked the patient to remove any removable prosthetic appliances
Assembled the required film holding instruments
Maxillary Centrals
Selected the correct exposure setting
Inserted the sensor vertically into anterior holder
Centered the sensor between the central incisors
Positioned the PID on the centre of the sensor
Image is of diagnostic quality
Maxillary Lateral/Cuspid Region
Selected the correct exposure setting
Inserted the sensor vertically into the anterior holder
Centered the sensor between the lateral and canine
Positioned the PID on the centre of the sensor
Image is of diagnostic quality
Maxillary Premolar Region
Selected the correct exposure setting
Inserted the sensor horizontally into the posterior holder
Centered the sensor on the premolars
Positioned the PID on the centre of the sensor
Image is of diagnostic quality
Maxillary Molar Region
Maxillary Molar Region
Inserted the sensor horizontally into the posterior holder
Centered the sensor on the second molar
Positioned the PID on the centre of the sensor
Image is of diagnostic quality
Bite Wings
Placed the sensor for a right molar bitewing exposure
PID centered on sensor
Used the correct exposure
Image is of diagnostic quality
Placed the sensor for a right premolar bitewing exposure
PID centered on sensor
Used the correct exposure
Image is of diagnostic quality
Placed the sensor for a left premolar bitewing exposure
PID centered on sensor
Used the correct exposure
Image is of diagnostic quality
Placed the sensor for a left molar bitewing exposure
PID centered on sensor
Used the correct exposure
Image is of diagnostic quality
Mandibular Centrals
Selected the correct exposure setting
Inserted the sensor vertically into anterior holder
Centered the sensor between the central incisors
Positioned the PID on the centre of the sensor
Image is of diagnostic quality
Mandibular Lateral/Cuspid Region
Selected the correct exposure setting
Inserted the sensor vertically into the anterior holder
Centered the sensor between the lateral and canine
Positioned the PID on the centre of the sensor
Image is of diagnostic quality
Mandibular Premolar Region
Selected the correct exposure setting
Inserted the sensor horizontally into the posterior holder
Centered the sensor on the premolars
Positioned the PID on the centre of the sensor
Image is of diagnostic quality
Mandibular Molar Region
Selected the correct exposure setting
Inserted the sensor horizontally into the posterior holder
Centered the sensor on the second molar
Positioned the PID on the centre of the sensor
Image is of diagnostic quality
Overall Evaluation
Completed in less than 45 minutes
Completed in 60 minutes or less
Images are of diagnostic quality and do not require more than 7 retakes
Documents chart according to protocol
Safety measures followed
Infection control protocols followed
Demonstrates professionalism and appropriate communication skills

License

Icon for the Creative Commons Attribution 4.0 International License

Dental Skills Manual Copyright © by NSCC is licensed under a Creative Commons Attribution 4.0 International License, except where otherwise noted.